A Body Area Network through Wireless Technology

Full Text Download |
Abstract
A physiological signal monitoring system and alerting system using wireless technology is presented. The two types
of physiological signal monitoring are captured from the body through leads and using the radio-frequency transmitting and
receiving module the data are interfaced to computer systems. Furthering using a developed user interface module the
captured signals are analyzed for checking abnormality. Any significant recordings are transmitted to the physicians hand
phone by using external serial SMS modem. ECG signal de-noising is conducted by using low-pass and high-pass filters.
EEG signals de-noising is conducted by using band-pass filters set. A comparative evaluation of the module with the manual
recording shows encouraging results. The ECG and EEG pattern are presented in this paper.
Keywords:bio signals, advanced signal processing.
I.Introduction
Wearable health monitoring systems integrated into a telemedicine system are novel information technology that will be
able to support early detection of abnormal conditions and prevention of its serious consequences [1,2]. A continuous
monitoring diagnostic procedure of a chronic condition or during supervised recovery from an acute event or surgical
procedure is needed these days. Wireless Body Area Network, (WBAN) consists of a set of mobile and compact
intercommunicating sensors, either wearable or implanted into the human body, which monitor vital body parameters and
movements [3-5]. This paper aims to present the design and implement of a portable device that can capture ECG
(Electrocardiogram) and EEG (Electroencephalography) signals from the human body and send those signals into Personal
Computer (PC) for continuous monitoring and analysis. In the event of any abnormal changes of in the captured signal, the
PC sends a message to doctor’s hand phone. ECG and EEG signals are captured from the electrodes and it is send to the
portable device that fixed on body. Here these signals will be amplified before sending it to RF transmitting device.
Transmitted signal is collected from the receiving module and the signals through a low pass filter before recording in the
database for analyzing.
Inside the developed program of the software ECG signals are de-noised using low-pas filter (FIR) and low-pass filter
(FIR). Using de-noised ECG signals, heart beat and amplitude of the R intervals are analyzed. EEG signal are de-noised by
using band pass-filters (FIR). EEG signals are then categorized according to the frequency ranges. This system was mainly
designed to analyze alpha-wave (α-wave). Leads and the potentials recorded at the various point in the test object is as
shown in Fig.1 The physiological signals are of low amplitude signals; therefore it is very important to amplify these signals
before being transmitted. Instrumentation amplifier can be used to amplify these mV range physiological signals. Fig.2 shows
the block diagram representation of the set-up.
References:
- Istepanian, RSH; Jovanov, E; Zhang, YT. Guest Editorial Introduction to the Special Section on M-Health: Beyond Seamless Mobility and Global Wireless Health-Care Connectivity. IEEE Transactions on Information Technology in Biomedicine. 2004;8:405–414. [PubMed].
- Wearable Technology. Special Issue of the IEEE Engineering in Medicine and Biology Magazine. 2003;22.
- Emil Jovanov, Aleksandar Milenkovic, Chris Otto,Piet C de Groen “A wireless body area network of intelligent motion sensors for computer assisted physical rehabilitation” J Neuroengineering Rehabil. 2005; 2: 6.
- Otis, BP; Rabaey, JM. A 300-μW 1.9-GHz CMOS Oscillator Utilizing Micromachined Resonators. IEEE Journal of Solid-State Circuits. 2003;38:1271–1274.
- Ghovanloo, M; Najafi, K. A BiCMOS Wireless Stimulator Chip for Micromachined Stimulating Microprobes. Proceedings of the Second Joint EMBS/BMES Conference. 2002. pp. 2113–2114.